Product Overview & Working Principle

 

The Industrial Pressure Transmitter is designed to measure gauge pressure, absolute pressure, differential pressure, and liquid level in industrial process systems. It converts the measured physical pressure into a stable 2-wire 4–20 mA analog output with superimposed HART 7.0 digital communication, ensuring seamless integration with PLC, DCS, and SCADA control systems.
Sensing & Signal Conditioning: Process media pressure acts upon an external isolating diaphragm, transmitting force via internal silicone fill fluid to the central piezoresistive/capacitive sensor cell. The raw signal is processed by an embedded 16-bit microprocessor executing real-time temperature compensation and signal linearization.
System Architecture: The modular electronic design completely separates the terminal wiring compartment from the sealed circuit board, safeguarding internal components against moisture and dust ingress in harsh outdoor installations.

 
  • Type C 4K BYOM Transmitter
    Type C 4K BYOM Transmitter The PTB1312 4K BYOM transmitter uses the pin definition of the Type-C interface, which includes the DP interface; therefore, as long as the DP interface contains a video
  • Type C 2K Transmitter
    Type C 2K Transmitter PTB1304 2K transmitter uses the pin definition of the Type-C interface, which includes the DP interface; therefore, as long as the DP interface contains a video stream, the
  • HDMI 4K BYOM Transmitter
    HDMI 4K BYOM Transmitter The biggest advantage of the HDMI transmitters, PTB1308 is that it can be directly plugged into the HDMI video output interface to project the video content output by the
  • HDMI 2K Transmitter
    HDMI 2K Transmitter The biggest advantage of the HDMI transmitters, PTB1305 is that it can be directly plugged into the HDMI video output interface to project the video content output by the
 

 

Measurement Types & Applications

Gauge Pressure (GP)

Measures process pressure relative to local atmospheric pressure. Ideal for standard industrial fluid and gas monitoring loops.

Liquid Level Measurement

Provides hydrostatic level monitoring in open or closed storage vessels through calibrated pressure configurations.

Absolute Pressure (AP)

Measures pressure relative to an absolute vacuum reference. Suitable for vacuum systems and applications where ambient barometric fluctuations must be excluded.

Differential Pressure (DP)

Measures the pressure drop across two independent process tappings. Widely utilized in flow metering, filter monitoring, and distillation column level control.

Core Performance & Technical Specifications

 

Parameter Category

Technical Specification

Measurement Types

Gauge Pressure (GP), Absolute Pressure (AP), Differential Pressure (DP), Liquid Level

Reference Accuracy

plus/minus 0.075 percent of calibrated span (optional high-accuracy tier available)

Long-Term Stability

plus/minus 0.1 percent of Upper Range Limit (URL) per 3 years

Turndown Ratio

Up to 100 to 1

Communication Output

2-wire, 4 to 20 mA DC with HART 7.0 protocol; Modbus RTU optional

Power Supply Loop

12.5 to 45 V DC (Standard HART); Intrinsically safe requires 12.5 to 30 V DC

Ingress Protection

IP67 / Type 4X (NEMA 4X)

Hazardous Area Ratings

Ex ia IIC T4 to T6 Ga/Gb (Intrinsically Safe); Ex db IIC T6 Gb (Flameproof / Explosion-Proof)

Operating Temperatures

Ambient: -40 deg C to 85 deg C; Process: -40 deg C to 125 deg C (up to 280 deg C via remote capillary seal)

Process Connections

1/2 inch NPT Female, 1/4 inch NPT Female, ANSI Flanges (1 inch to 3 inch, Class 150/300), Tri-Clamp

Wetted Materials

Diaphragm: 316L Stainless Steel, Hastelloy C-276, Tantalum, Monel; Process Flange: 316L SS, Carbon Steel

Thermal Drift Defense: Integrated ambient temperature sensors work alongside onboard firmware to apply real-time polynomial compensation, restricting thermal error to less than plus/minus 0.05 percent per 10 deg C swing.

Overpressure Resilience: Withstands temporary process overloads up to 4 times the maximum calibrated range without zero shift or permanent diaphragm deformation. 

 

 

Manufacturing & Quality Control

True manufacturing capability and material traceability verified at every production stage:

5-Axis CNC & Orbital Welding: Sensor bodies and process flanges are machined from solid forged bar stock on high-precision 5-axis machining centers, followed by automatic orbital TIG welding to secure leak-free hermetic seals.

High-Vacuum Oil Filling: Silicone fill fluid is injected inside a high-vacuum chamber (less than 10 to the power of -3 Pa) to completely eliminate micro-air pockets, preventing measurement hysteresis and thermal lag.

Thermal Stress Burn-In: Every completed sensor module undergoes a mandatory 72-hour thermal cycling burn-in process (cycling between -40 deg C and 90 deg C under active pressure load) to stabilize piezoresistive crystal lattices.

NIST-Traceable Calibration: Individual units are calibrated on automated multi-point pressure controllers. Every shipment includes a factory calibration certificate detailing 5-point linearity and hysteresis test logs.

Quality Management: Produced in facilities operating strictly under ISO 9001:2015 and hazardous production quality assurance guidelines.

Type C 4K BYOM Transmitter

 

 

Technical & Purchasing FAQs

 

 

Q: What is the standard lead time for stock configurations versus custom process ranges?

A: Standard catalog units (standard pressure ranges, 316L wetted parts, 4-20mA/HART output) ship within 3 to 5 business days for quantities under 50 units. Custom calibrated spans, specialized flange sizes, or exotic wetted materials (Hastelloy/Tantalum) require 2 to 3 weeks. Expedited manufacturing slots are available for plant turnaround schedules.

Q: Are these transmitters fully compatible with legacy HART communicators and asset management software?

A: Yes. The units support HART 7.0 protocols and integrate smoothly with standard field communicators and asset management tools utilizing standard DD (Device Description) and EDDL files.

Q: How do you handle hazardous area compliance for international oil and gas projects?

A: We supply certified units featuring Ex ia IIC T4 to T6 (Intrinsically Safe) for zone 0/1 environments requiring safety barriers, and Ex db IIC T6 (Flameproof/Explosion-Proof) enclosures for heavy industrial zones without barriers. Complete third-party test reports and certificates are provided prior to shipment.

Q: Can the wetted parts withstand extreme corrosive media like concentrated acids?

A: For standard corrosive loops, we provide wetted parts in Hastelloy C-276. For severe oxidizing chemicals (such as boiling hydrochloric acid or wet chlorine), we supply solid Tantalum diaphragms welded directly to the process connection. Material review is available through our engineering desk.

Q: What is your standard warranty and RMA technical support procedure?

A: All units carry a 12-month standard warranty from the date of installation (or 18 months from shipment) covering workmanship and material defects. In the unlikely event of a return, our quality lab issues an inspection report and root-cause analysis within 5 business days of receipt.

Q: Are direct drop-in replacements available for existing control panel wiring?

A: Yes. The physical housing and terminal block layouts match standard 2-wire industrial instrumentation footprints, allowing direct mechanical and electrical drop-in replacement without control panel rewiring.

As one of the most professional transmitter manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to buy customized transmitter made in China here from our factory. Contact us for quotation.

Send Inquiry